{"product_id":"ooitech-solar-panel-laminator-complete-product-catalogue","title":"Ooitech Solar Panel Laminator Complete Product Catalogue","description":"\u003cblockquote\u003e\n\u003cp\u003eOoitech solar panel laminator full catalogue: 10 models, technical specs comparison, system descriptions, safety controls\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch4\u003eOoitech Solar Panel Laminator Complete Product Catalogue\u003c\/h4\u003e\n\u003cp\u003eOoitech solar panel laminator full catalogue: 10 models, technical specs comparison, system descriptions, safety controls\u003c\/p\u003e\n\u003chr\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e This is Ooitech's complete solar panel laminator catalogue: ten models covering semi-automatic and fully automatic machines, from a 600 mm by 600 mm laboratory chamber up to 2600 mm by 1500 mm production platens. It includes the model naming convention, a technical specification comparison across all ten machines, individual specifications for each, common system descriptions, safety controls, key component brands, factory and installation requirements, warranty terms and operating notes. Chamber size is the first decision, because it fixes how many modules load at once; the second is whether one or two chambers suit your cycle, since a double-chamber machine keeps the vacuum pumps working while the other side loads. Temperature uniformity across the platen is the specification that decides laminate quality: a cold corner leaves uncured encapsulant that fails years later. Silicone oil and vacuum pump selection follow from the chamber volume and the cycle time you need.\u003c\/p\u003e\n\u003cp\u003ePV Module Manufacturing · by Jerry, Ooitech\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\u003ca href=\"#overview\"\u003eProduct Overview \u0026amp; Application\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#model-naming\"\u003eModel Naming Convention\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#comparison\"\u003eTechnical Specification Comparison Table (All Models)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#models\"\u003eIndividual Model Specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#systems\"\u003eCommon System Descriptions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#safety\"\u003eSafety Control\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#parts\"\u003eKey Components \u0026amp; Brands\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#factory\"\u003eFactory \/ Installation Requirements\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#warranty\"\u003eWarranty \u0026amp; After-Sales Service\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#opnotes\"\u003eOperating \u0026amp; Safety Notes (User Manual Extract)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e1. Product Overview \u0026amp; Application\u003c\/h2\u003e\n\u003cp\u003eThe solar panel laminator is the most critical process equipment in the photovoltaic module production line. It bonds multiple layers of materials — \u003cstrong\u003eEVA \u003ca href=\"https:\/\/www.ooitech.com\/EVA-POE-EPE-Encapsulant-Film-for-Solar-Panel-Manufacturing-Complete-Technical-Guide.html\"\u003eencapsulant\u003c\/a\u003e, tempered glass, \u003ca href=\"https:\/\/www.ooitech.com\/Photovoltaic-Backsheet-The-Critical-Protective-Layer-for-Solar-Modules.html\"\u003ebacksheet\u003c\/a\u003e, and solar cells\u003c\/strong\u003e — together through a controlled combination of heat and vacuum inside a sealed lamination chamber.\u003c\/p\u003e\n\u003cp\u003eOoitech offers a complete range of laminators from compact semi-automatic bench-top models to large-scale fully-automatic double-layer, triple-chamber production lines. All models are compatible with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMono-crystalline silicon solar modules\u003c\/li\u003e\n\u003cli\u003ePoly-crystalline silicon solar modules\u003c\/li\u003e\n\u003cli\u003eDouble-glass solar modules (bifacial)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ooitech.com\/what-is-topcon-solar-cell-a-complete-guide-to-tunnel-oxide-passivated-contact-technology.html\"\u003eTOPCon\u003c\/a\u003e, HJT and other advanced cell technologies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e2. Model Naming Convention\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Letter\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eSemi-automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eSingle chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003eDouble chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eTriple chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eDouble layer (stacked)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003eElectric heating (when used as suffix; \"DD\" = double layer double chamber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumeric suffix (e.g. 2787, 2658): represents effective lamination area dimensions (Width × Length in mm, abbreviated)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e3. Technical Specification Comparison Table — All Models\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eOCY-H600D\u003c\/th\u003e\n\u003cth\u003eOCY-1111\u003c\/th\u003e\n\u003cth\u003eOTCY-2615\u003c\/th\u003e\n\u003cth\u003eOTCY-2446\u003c\/th\u003e\n\u003cth\u003eOTCY-2658(Single)\u003c\/th\u003e\n\u003cth\u003eOTCY-2666\u003c\/th\u003e\n\u003cth\u003eOTCY-2658(Double)\u003c\/th\u003e\n\u003cth\u003eOTCY-2787D\u003c\/th\u003e\n\u003cth\u003eOTCY-2787DD\u003c\/th\u003e\n\u003cth\u003eOTCY-BT2787\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e— Basic Configuration —\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Mode\u003c\/td\u003e\n\u003ctd\u003eSemi-Auto\u003c\/td\u003e\n\u003ctd\u003eSemi-Auto\u003c\/td\u003e\n\u003ctd\u003eSemi-Auto\u003c\/td\u003e\n\u003ctd\u003eFull Auto\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003ctd\u003eFull Auto\u003c\/td\u003e\n\u003ctd\u003eFull Auto\u003c\/td\u003e\n\u003ctd\u003eFull Auto\u003c\/td\u003e\n\u003ctd\u003eFull Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003ctd\u003e1 Lam.\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003ctd\u003e1 Lam. + 1 Cur.\u003c\/td\u003e\n\u003ctd\u003e1 Lam. + 1 Cur.\u003c\/td\u003e\n\u003ctd\u003e2 Lam. + 2 Cur.(Double Layer)\u003c\/td\u003e\n\u003ctd\u003e2 Lam. + 2 Cur. + 2 Cool.(Double Layer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Mode\u003c\/td\u003e\n\u003ctd\u003eElectric\u003c\/td\u003e\n\u003ctd\u003eElectric\u003c\/td\u003e\n\u003ctd\u003eElectric\u003c\/td\u003e\n\u003ctd\u003eOil\u003c\/td\u003e\n\u003ctd\u003eOil\u003c\/td\u003e\n\u003ctd\u003eOil\u003c\/td\u003e\n\u003ctd\u003eOil\u003c\/td\u003e\n\u003ctd\u003eOil\u003c\/td\u003e\n\u003ctd\u003eOil\u003c\/td\u003e\n\u003ctd\u003eOil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e— Dimensions \u0026amp; Capacity —\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamination Area (mm)\u003c\/td\u003e\n\u003ctd\u003e600 × 600\u003c\/td\u003e\n\u003ctd\u003e1100 × 1100\u003c\/td\u003e\n\u003ctd\u003e2600 × 1500\u003c\/td\u003e\n\u003ctd\u003e4600 × 2400\u003c\/td\u003e\n\u003ctd\u003e2600 × 5800\u003c\/td\u003e\n\u003ctd\u003e2600 × 6600\u003c\/td\u003e\n\u003ctd\u003e5800 × 2600\u003c\/td\u003e\n\u003ctd\u003e8700 × 2700\u003c\/td\u003e\n\u003ctd\u003e8700 × 2700× 2 layers\u003c\/td\u003e\n\u003ctd\u003e8700 × 2700× 2 layers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Net Height (mm)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size (m)\u003c\/td\u003e\n\u003ctd\u003e1.1×1.1×1.0\u003c\/td\u003e\n\u003ctd\u003e1.5×2.0×1.4\u003c\/td\u003e\n\u003ctd\u003e3.1×2.5×1.4\u003c\/td\u003e\n\u003ctd\u003e14.98×3.4×1.8\u003c\/td\u003e\n\u003ctd\u003e18.5×3.58×1.8\u003c\/td\u003e\n\u003ctd\u003e21.1×3.58×1.8\u003c\/td\u003e\n\u003ctd\u003e21.3×3.58×1.8\u003c\/td\u003e\n\u003ctd\u003e37.3×3.68×1.8\u003c\/td\u003e\n\u003ctd\u003e37.3×4.88×3.4\u003c\/td\u003e\n\u003ctd\u003e47.2×4.9×3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 T\u003c\/td\u003e\n\u003ctd\u003e2.3 T\u003c\/td\u003e\n\u003ctd\u003e5 T\u003c\/td\u003e\n\u003ctd\u003e16 T\u003c\/td\u003e\n\u003ctd\u003e25 T\u003c\/td\u003e\n\u003ctd\u003e25 T\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e128 T\u003c\/td\u003e\n\u003ctd\u003e170 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e— Power \u0026amp; Electrical —\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 380V \/ 50Hz \/ 3-Phase 5-Wire (all models)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e5 kW\u003c\/td\u003e\n\u003ctd\u003e11.5 kW\u003c\/td\u003e\n\u003ctd\u003e33 kW\u003c\/td\u003e\n\u003ctd\u003e70 kW\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003ctd\u003e185 kW\u003c\/td\u003e\n\u003ctd\u003e190 kW\u003c\/td\u003e\n\u003ctd\u003e395 kW\u003c\/td\u003e\n\u003ctd\u003e460 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Working Power\u003c\/td\u003e\n\u003ctd\u003e1.5 kW\u003c\/td\u003e\n\u003ctd\u003e3.5 kW\u003c\/td\u003e\n\u003ctd\u003e≤8.5 kW\u003c\/td\u003e\n\u003ctd\u003e≤30 kW\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e≤45 kW\u003c\/td\u003e\n\u003ctd\u003e≤95 kW\u003c\/td\u003e\n\u003ctd\u003e95 kW\u003c\/td\u003e\n\u003ctd\u003e≤190 kW\u003c\/td\u003e\n\u003ctd\u003e≤220 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e3+1.2 kW\u003c\/td\u003e\n\u003ctd\u003e8.5 kW\u003c\/td\u003e\n\u003ctd\u003e27 kW\u003c\/td\u003e\n\u003ctd\u003e54 kW\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003ctd\u003e72 kW\u003c\/td\u003e\n\u003ctd\u003e72 kW × 2\u003c\/td\u003e\n\u003ctd\u003e72 kW × 2\u003c\/td\u003e\n\u003ctd\u003e72 kW × 4\u003c\/td\u003e\n\u003ctd\u003e72 kW × 2 (per layer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e— Temperature —\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30–200°C\u003c\/td\u003e\n\u003ctd\u003e30–200°C\u003c\/td\u003e\n\u003ctd\u003e30–200°C\u003c\/td\u003e\n\u003ctd\u003e30–180°C\u003c\/td\u003e\n\u003ctd\u003e30–180°C\u003c\/td\u003e\n\u003ctd\u003e30–180°C\u003c\/td\u003e\n\u003ctd\u003e30–180°C\u003c\/td\u003e\n\u003ctd\u003e30–180°C\u003c\/td\u003e\n\u003ctd\u003e30–180°C\u003c\/td\u003e\n\u003ctd\u003e30–180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003e±2°C\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003ctd\u003e≤±1.5°C\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003ctd\u003e≤±1°C\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003ctd\u003e≤±1.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Control Points\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eStandard per chamber\u003c\/td\u003e\n\u003ctd\u003e5 per chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e— Vacuum —\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree (operating)\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003e40 Pa\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003e40 Pa\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa (ult. 40 Pa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Time (adjustable)\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003eVRD-24 (24 m³\/h)\u003c\/td\u003e\n\u003ctd\u003e2X-30 (30 L\/s)\u003c\/td\u003e\n\u003ctd\u003e2X-30\u003c\/td\u003e\n\u003ctd\u003e2X-70\u003c\/td\u003e\n\u003ctd\u003e2X-70 + ZJP600\u003c\/td\u003e\n\u003ctd\u003e2X-70 + ZJP600\u003c\/td\u003e\n\u003ctd\u003e2X-70+ZJP600 \/ 2X-70\u003c\/td\u003e\n\u003ctd\u003e2X-70+ZJP600 \/ 2X-70\u003c\/td\u003e\n\u003ctd\u003e2×(2X-70+ZJP600) \/ 2×2X-70\u003c\/td\u003e\n\u003ctd\u003e2×2X-70+ZJP600 \/ 2×2X-70 \/ 2X-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e— Air Supply —\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply Pressure\u003c\/td\u003e\n\u003ctd\u003e0.6 ~ 0.8 MPa (all models)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥200 L\/min\u003c\/td\u003e\n\u003ctd\u003e≥300 L\/min\u003c\/td\u003e\n\u003ctd\u003e≥300 L\/min\u003c\/td\u003e\n\u003ctd\u003e≥400 L\/min\u003c\/td\u003e\n\u003ctd\u003e≥400 L\/min\u003c\/td\u003e\n\u003ctd\u003e≥600 L\/min\u003c\/td\u003e\n\u003ctd\u003e≥800 L\/min\u003c\/td\u003e\n\u003ctd\u003e≥800 L\/min\u003c\/td\u003e\n\u003ctd\u003e≥1000 L\/min\u003c\/td\u003e\n\u003ctd\u003e≥800 L\/min × 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e— Performance —\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork Cycle\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003e≤18 min\u003c\/td\u003e\n\u003ctd\u003e≤18 min\u003c\/td\u003e\n\u003ctd\u003e≤18 min\u003c\/td\u003e\n\u003ctd\u003e≤9 min\u003c\/td\u003e\n\u003ctd\u003e≤9 min\u003c\/td\u003e\n\u003ctd\u003e≤9 min\u003c\/td\u003e\n\u003ctd\u003e≤9 min (per layer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e98%\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e≥99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥ 10 years (all models)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConveying Speed\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoading \/ Unloading\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer opt.)\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer opt.)\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer opt.)\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer opt.)\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer opt.)\u003c\/td\u003e\n\u003ctd\u003eStacked belt \/ Stacked SS rollers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC (all models)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking height (cover open)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e100–120 mm\u003c\/td\u003e\n\u003ctd\u003e100–120 mm\u003c\/td\u003e\n\u003ctd\u003e100–120 mm\u003c\/td\u003e\n\u003ctd\u003e100–150 mm\u003c\/td\u003e\n\u003ctd\u003e100–120 mm\u003c\/td\u003e\n\u003ctd\u003e100–120 mm\u003c\/td\u003e\n\u003ctd\u003e100–120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. cover height (maint.)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e≥250 mm\u003c\/td\u003e\n\u003ctd\u003e≥250 mm\u003c\/td\u003e\n\u003ctd\u003e≥250 mm\u003c\/td\u003e\n\u003ctd\u003e≥250 mm\u003c\/td\u003e\n\u003ctd\u003e≥250 mm\u003c\/td\u003e\n\u003ctd\u003e≥250 mm\u003c\/td\u003e\n\u003ctd\u003e≥250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAeration Rate\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e0–50 L\/s\u003c\/td\u003e\n\u003ctd\u003e0–50 L\/s\u003c\/td\u003e\n\u003ctd\u003e0–50 L\/s\u003c\/td\u003e\n\u003ctd\u003e0–5 L\/s\u003c\/td\u003e\n\u003ctd\u003e0–70 L\/s\u003c\/td\u003e\n\u003ctd\u003e0–50 L\/s\u003c\/td\u003e\n\u003ctd\u003e0–50 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e4. Individual Model Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLamination Area\u003c\/th\u003e\n\u003cth\u003e600 × 600 mm\u003c\/th\u003e\n\u003cth\u003eHeating Mode\u003c\/th\u003e\n\u003cth\u003eElectricity Heating (Double-side)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e5 kW\u003c\/td\u003e\n\u003ctd\u003eAvg. Working Power\u003c\/td\u003e\n\u003ctd\u003e1.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e3 kW + 1.2 kW\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003eVRD-24 (24 m³\/h) — Feiyue brand\u003c\/td\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥200 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Cycle\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size\u003c\/td\u003e\n\u003ctd\u003e1100 × 1100 × 1000 mm\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: Heating time from room temperature to 145°C:\u0026lt;60 minutes. Vacuum time to reach 100Pa: \u0026lt;120 seconds.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLamination Area\u003c\/th\u003e\n\u003cth\u003e1100 × 1100 mm\u003c\/th\u003e\n\u003cth\u003eHeating Mode\u003c\/th\u003e\n\u003cth\u003eElectricity Heating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e11.5 kW\u003c\/td\u003e\n\u003ctd\u003eAvg. Working Power\u003c\/td\u003e\n\u003ctd\u003e3.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e8.5 kW\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003e2X-30 (30 L\/s) — Sichuang Nanguang\u003c\/td\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥300 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Cycle\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size\u003c\/td\u003e\n\u003ctd\u003e1500 × 2000 × 1400 mm\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.3 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eNote: Heating time from room temperature to 145°C:\u0026lt;50 minutes. Vacuum time to reach 100Pa: \u0026lt;120 seconds.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLamination Area\u003c\/th\u003e\n\u003cth\u003e2600 × 1500 mm\u003c\/th\u003e\n\u003cth\u003eHeating Mode\u003c\/th\u003e\n\u003cth\u003eElectric Heating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e33 kW\u003c\/td\u003e\n\u003ctd\u003eAvg. Working Power\u003c\/td\u003e\n\u003ctd\u003e≤8.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e27 kW\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree\u003c\/td\u003e\n\u003ctd\u003e40 Pa\u003c\/td\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003e2X-30\u003c\/td\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥300 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Cycle\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size \/ Weight\u003c\/td\u003e\n\u003ctd\u003e3.1 × 2.5 × 1.4 m \/ 5 T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eElectric heating with module control for improved temperature uniformity. Heating to 145°C:\u0026lt;50 minutes. Vacuum to 100Pa: \u0026lt;120 seconds.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLamination Area\u003c\/th\u003e\n\u003cth\u003e4600 × 2400 mm\u003c\/th\u003e\n\u003cth\u003eHeating Mode\u003c\/th\u003e\n\u003cth\u003eOil Heating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e70 kW\u003c\/td\u003e\n\u003ctd\u003eAvg. Working Power\u003c\/td\u003e\n\u003ctd\u003e≤30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e54 kW\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Control Points\u003c\/td\u003e\n\u003ctd\u003e≥5\u003c\/td\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003e2X-70 (+ ZPJ300 Roots — user spec.)\u003c\/td\u003e\n\u003ctd\u003eAeration Rate\u003c\/td\u003e\n\u003ctd\u003e0–50 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥400 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork Cycle\u003c\/td\u003e\n\u003ctd\u003e≤18 min\u003c\/td\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003e98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Config.\u003c\/td\u003e\n\u003ctd\u003e1 Lamination Chamber\u003c\/td\u003e\n\u003ctd\u003eLoading \/ Unloading\u003c\/td\u003e\n\u003ctd\u003eBelt loading \/ SS roller discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC (Siemens)\u003c\/td\u003e\n\u003ctd\u003eConveying Speed\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size \/ Weight\u003c\/td\u003e\n\u003ctd\u003e14.98 × 3.4 × 1.8 m \/ 16 T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLamination Area\u003c\/th\u003e\n\u003cth\u003e2600 × 5800 mm\u003c\/th\u003e\n\u003cth\u003eHeating Mode\u003c\/th\u003e\n\u003cth\u003eOil Heating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003ctd\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±1.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Control Points\u003c\/td\u003e\n\u003ctd\u003e≥5\u003c\/td\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa (ult.\u0026lt;40 Pa)\u003c\/td\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min (adj.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003e2X-70 + ZJP600 Roots\u003c\/td\u003e\n\u003ctd\u003eAeration Rate\u003c\/td\u003e\n\u003ctd\u003e0–50 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥400 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumping Rate\u003c\/td\u003e\n\u003ctd\u003e≥600 m³\/h (100Pa in\u0026lt;90s)\u003c\/td\u003e\n\u003ctd\u003eWork Cycle\u003c\/td\u003e\n\u003ctd\u003e≤18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Config.\u003c\/td\u003e\n\u003ctd\u003eSingle Chamber\u003c\/td\u003e\n\u003ctd\u003eLoading \/ Unloading\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC (Siemens)\u003c\/td\u003e\n\u003ctd\u003eConveying Speed\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size \/ Weight\u003c\/td\u003e\n\u003ctd\u003e18.5 × 3.58 × 1.8 m \/ 25 T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLamination Area\u003c\/th\u003e\n\u003cth\u003e2600 × 6600 mm\u003c\/th\u003e\n\u003cth\u003eHeating Mode\u003c\/th\u003e\n\u003cth\u003eOil Heating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e90 kW\u003c\/td\u003e\n\u003ctd\u003eAvg. Working Power\u003c\/td\u003e\n\u003ctd\u003e≤45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e72 kW\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Control Points\u003c\/td\u003e\n\u003ctd\u003e≥5\u003c\/td\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree\u003c\/td\u003e\n\u003ctd\u003e40 Pa\u003c\/td\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min (adj.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003e2X-70 + ZJP600 Roots\u003c\/td\u003e\n\u003ctd\u003eAeration Rate\u003c\/td\u003e\n\u003ctd\u003e0–50 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥600 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumping Rate\u003c\/td\u003e\n\u003ctd\u003e≥600 m³\/h (100Pa in\u0026lt;90s)\u003c\/td\u003e\n\u003ctd\u003eWork Cycle\u003c\/td\u003e\n\u003ctd\u003e≤18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Config.\u003c\/td\u003e\n\u003ctd\u003eSingle Chamber\u003c\/td\u003e\n\u003ctd\u003eLoading \/ Unloading\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC (Siemens)\u003c\/td\u003e\n\u003ctd\u003eConveying Speed\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size \/ Weight\u003c\/td\u003e\n\u003ctd\u003e21.1 × 3.58 × 1.8 m \/ 25 T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLamination Area\u003c\/th\u003e\n\u003cth\u003e5800 × 2600 mm (Double chamber)\u003c\/th\u003e\n\u003cth\u003eHeating Mode\u003c\/th\u003e\n\u003cth\u003eOil Heating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e185 kW\u003c\/td\u003e\n\u003ctd\u003eAvg. Working Power\u003c\/td\u003e\n\u003ctd\u003e≤95 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e72 kW × 2\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±2°C\u003c\/td\u003e\n\u003ctd\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Control Points\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump (Lam.)\u003c\/td\u003e\n\u003ctd\u003e2X-70 + ZJP600 Roots\u003c\/td\u003e\n\u003ctd\u003eVacuum Pump (Cur.)\u003c\/td\u003e\n\u003ctd\u003e2X-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAeration Rate\u003c\/td\u003e\n\u003ctd\u003e0–5 L\/s\u003c\/td\u003e\n\u003ctd\u003ePumping Rate\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;90s to 100Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥800 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork Cycle\u003c\/td\u003e\n\u003ctd\u003e≤9 min\u003c\/td\u003e\n\u003ctd\u003eChamber Config.\u003c\/td\u003e\n\u003ctd\u003e1 Lamination + 1 Curing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoading \/ Unloading\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer optional)\u003c\/td\u003e\n\u003ctd\u003eConveying Speed\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC (Siemens)\u003c\/td\u003e\n\u003ctd\u003eCuring Cover Height\u003c\/td\u003e\n\u003ctd\u003e120–150 mm (working); ≥250 mm (maint.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size\u003c\/td\u003e\n\u003ctd\u003e21.3 × 3.58 × 1.8 m\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLamination Area\u003c\/th\u003e\n\u003cth\u003e8700 × 2700 mm\u003c\/th\u003e\n\u003cth\u003eHeating Mode\u003c\/th\u003e\n\u003cth\u003eOil Heating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e190 kW\u003c\/td\u003e\n\u003ctd\u003eAvg. Working Power\u003c\/td\u003e\n\u003ctd\u003e95 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e72 kW × 2\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Control Points\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa (ult. 40 Pa)\u003c\/td\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump (Lam.)\u003c\/td\u003e\n\u003ctd\u003e2X-70 + ZJP600 Roots; pumping rate ≥630 m³\/h (100Pa in\u0026lt;90s)\u003c\/td\u003e\n\u003ctd\u003eVacuum Pump (Cur.)\u003c\/td\u003e\n\u003ctd\u003e2X-70 rotary vane; ≥70 L\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAeration Rate\u003c\/td\u003e\n\u003ctd\u003e0–70 L\/s\u003c\/td\u003e\n\u003ctd\u003eInflation Valve\u003c\/td\u003e\n\u003ctd\u003eSMC VXZ260KG (zero differential pressure, two-way solenoid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥800 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork Cycle\u003c\/td\u003e\n\u003ctd\u003e≤9 min\u003c\/td\u003e\n\u003ctd\u003eChamber Config.\u003c\/td\u003e\n\u003ctd\u003e1 Lamination + 1 Curing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoading \/ Unloading\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer optional)\u003c\/td\u003e\n\u003ctd\u003eConveying Speed\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC (Siemens\/Kunlun)\u003c\/td\u003e\n\u003ctd\u003eKey Pneumatics\u003c\/td\u003e\n\u003ctd\u003eJapanese SMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size\u003c\/td\u003e\n\u003ctd\u003e37.3 × 3.68 × 1.8 m\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLamination Area\u003c\/th\u003e\n\u003cth\u003e8700 × 2700 mm × 2 layers\u003c\/th\u003e\n\u003cth\u003eHeating Mode\u003c\/th\u003e\n\u003cth\u003eOil Heating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e395 kW\u003c\/td\u003e\n\u003ctd\u003eAvg. Working Power\u003c\/td\u003e\n\u003ctd\u003e≤190 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e72 kW × 4\u003c\/td\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003ctd\u003eTemp. Uniformity\u003c\/td\u003e\n\u003ctd\u003e≤±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Control Point\u003c\/td\u003e\n\u003ctd\u003eStandard per chamber\u003c\/td\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003e2× (2X-70 + ZJP600) Roots (lam.) \/ 2× (2X-70) rotary (cur.)\u003c\/td\u003e\n\u003ctd\u003ePumping Rate\u003c\/td\u003e\n\u003ctd\u003e≥630 m³\/h (lam., 100Pa\u0026lt;90s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAeration Rate\u003c\/td\u003e\n\u003ctd\u003e0–50 L\/s\u003c\/td\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressed Air Flow\u003c\/td\u003e\n\u003ctd\u003e≥1000 L\/min\u003c\/td\u003e\n\u003ctd\u003eWork Cycle\u003c\/td\u003e\n\u003ctd\u003e≤9 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Config.\u003c\/td\u003e\n\u003ctd\u003e2 Lamination + 2 Curing (Double Layer)\u003c\/td\u003e\n\u003ctd\u003eLoading \/ Unloading\u003c\/td\u003e\n\u003ctd\u003eBelt \/ SS rollers (buffer optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eTouch Screen + PLC\u003c\/td\u003e\n\u003ctd\u003eConveying Speed\u003c\/td\u003e\n\u003ctd\u003e4–14 m\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Size \/ Weight\u003c\/td\u003e\n\u003ctd\u003e37.3 × 4.88 × 3.4 m \/ 128 T (Ground bearing: 3.0 T\/m²)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFactory Requirements (OTCY-2787DD)\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e380V\/50Hz, 3-phase 5-wire. Peak: 395 kW; Operating: 190 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressed Air\u003c\/td\u003e\n\u003ctd\u003ePressure: 0.8 MPa (min 0.6 MPa); Peak flow: 1000 L\/min; Operating flow: 600 L\/min; Interface: Φ16 mm × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Water\u003c\/td\u003e\n\u003ctd\u003eNormal circulation (for vacuum pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExhaust Demand\u003c\/td\u003e\n\u003ctd\u003eTemperature\u0026lt;180°C; Flow: 30 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClean Room\u003c\/td\u003e\n\u003ctd\u003eISO Class 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor Flatness\u003c\/td\u003e\n\u003ctd\u003e±10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Conditioning\u003c\/td\u003e\n\u003ctd\u003e25 ± 5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFull Name\u003c\/th\u003e\n\u003cth\u003eDouble Layer Triple Chamber Oil Heating Solar PV Module Laminator\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamination Area\u003c\/td\u003e\n\u003ctd\u003e2700 × 8700 mm × 2 layers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e460 kW (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e72 kW × 2 (per layer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e30°C – 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Precision\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber Height\u003c\/td\u003e\n\u003ctd\u003e40 mm (lam.); working cover: 100–120 mm; max: ≥250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degree (op.)\u003c\/td\u003e\n\u003ctd\u003e40–100 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Time\u003c\/td\u003e\n\u003ctd\u003e5–30 min (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e0.6–0.8 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork Cycle\u003c\/td\u003e\n\u003ctd\u003e≤9 min (per layer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine Weight\u003c\/td\u003e\n\u003ctd\u003e170 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon Gel Plate Life\u003c\/td\u003e\n\u003ctd\u003e≥3000 uses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Platform\u003c\/td\u003e\n\u003ctd\u003eIndependent Double Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduction Line Docking Height\u003c\/td\u003e\n\u003ctd\u003eLower layer: 950 ± 30 mm; Upper layer: 2630 ± 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoundary Dimension\u003c\/td\u003e\n\u003ctd\u003e47.2 × 4.9 × 3.4 m (incl. 2nd layer maintenance platform)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Machine Dimension\u003c\/td\u003e\n\u003ctd\u003e30.5 m (L) × 3.7 m (W) × 3.4 m (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2nd Layer Maintenance Platform\u003c\/td\u003e\n\u003ctd\u003eWidth: 600 mm; Height: 1800 mm; Guardrail height: 900 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003e≥10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eStructure Summary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit Constitution: Loading stage ×2, Process stage I ×2 (Laminating), Process stage II ×2 (Solidifying), Cooling stage ×2, Unloading stage ×2\u003c\/li\u003e\n\u003cli\u003eVacuum equipment: Ten sets of 2X-70 rotary vane pumps, two sets of ZJP600 Roots pumps\u003c\/li\u003e\n\u003cli\u003eHeating: Four sets of 72 kW heating stations (SD320 thermal oil)\u003c\/li\u003e\n\u003cli\u003eEach laminating chamber is independent; each layer can execute lamination separately\u003c\/li\u003e\n\u003cli\u003eUpper and lower high-temperature cloth systems equipped with roller brush devices for residue elimination\u003c\/li\u003e\n\u003cli\u003eSpecialized maintenance platform with climbing ladder for 2nd-floor access (600 mm wide, 1800 mm height, 900 mm guardrail)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCooling Stage (unique to BT2787)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSame structural form as process stage, but configured with an industrial chiller for water circulation cooling of modules exiting the process chambers\u003c\/li\u003e\n\u003cli\u003eCooling base plate: Q235 steel, 40 mm thickness, finely ground surface; internal perforations allow coolant flow\u003c\/li\u003e\n\u003cli\u003eTemperature measurement points on base plate: ≥5, real-time display\u003c\/li\u003e\n\u003cli\u003eCooling stage vacuum pump: rotary vane pump, ≥70 L\/s; 100 Pa in\u0026lt;90s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e5. Common System Descriptions\u003c\/h2\u003e\n\u003cp\u003eThe following descriptions apply to all full-automatic oil-heating models (OTCY-2446, 2658, 2666, 2787D, 2787DD, BT2787). Semi-automatic electric models share the same control and safety logic but have simplified mechanical structure.\u003c\/p\u003e\n\u003ch3\u003e5.1 Feeding System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe feeding stage uses an \u003cstrong\u003eanti-deviation conveyor belt\u003c\/strong\u003e to perfectly transition modules to the main laminating unit.\u003c\/li\u003e\n\u003cli\u003eControlled by \u003cstrong\u003efrequency conversion system + photoelectric positioning system + encoder fool-proofing system\u003c\/strong\u003e. Transmission speed is continuously adjustable from \u003cstrong\u003e4 to 14 m\/min\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eThree operating modes available: \u003cstrong\u003eAuto feeding, Manual feeding, and Emergency management\u003c\/strong\u003e (via transmission inching button).\u003c\/li\u003e\n\u003cli\u003ePhotoelectric sensor at the end of the conveyor belt provides module protection and positioning. If positioning deviation is detected, modules cannot enter the lamination section (alarm triggered).\u003c\/li\u003e\n\u003cli\u003eDouble-layer (BT2787, 2787DD) models use \u003cstrong\u003estacked belt loading platforms\u003c\/strong\u003e — each layer has its own independent loading unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e5.2 Laminating \/ Curing Section\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChamber structure:\u003c\/strong\u003e Each lamination chamber consists of an upper chamber (upper box) and a lower heating plate, separated by a silica gel plate with a sealable bead\/pressing frame, forming two independent sub-chambers (upper and lower).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating plate:\u003c\/strong\u003e Made of 60 mm thick Q235 steel plate. Surface is finished by fine grinding; surface irregularity ≤200 µm\/m². Double-inlet and double-outlet pipeline design for heat-conducting oil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating rate:\u003c\/strong\u003e Not less than 1.5°C\/min.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature deviation:\u003c\/strong\u003e ≤±2°C (standard); ≤±1.5°C (premium models).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature measurement:\u003c\/strong\u003e ≥5 points per heating plate, displayed in real-time on touch screen.\u003c\/li\u003e\n\u003cli\u003eEach sub-chamber can be \u003cstrong\u003eindependently vacuumed and inflated\u003c\/strong\u003e. The vacuum value is set and controlled — supports segmented \/ staged lamination profiles. A SMC pressure sensor monitors real-time pressure; a Pa-class vacuum gauge is installed in the lower chamber.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaminating section vacuum pump:\u003c\/strong\u003e 2X-70 rotary vane + ZJP600 Roots pump set. Pumping rate ≥630 m³\/h (OTCY-2787D\/DD) or ≥600 m³\/h (2658\/2666). Time to 100 Pa:\u0026lt;90 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCuring section vacuum pump:\u003c\/strong\u003e 2X-70 rotary vane pump. Pumping rate ≥70 L\/s. Time to 100 Pa:\u0026lt;90 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover lifting:\u003c\/strong\u003e Working opening height 100–120 mm; ultimate opening height (maintenance) ≥250 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositioning accuracy:\u003c\/strong\u003e Gear motor + frequency control + encoder system. Repeat positioning accuracy within ±10 mm.\u003c\/li\u003e\n\u003cli\u003eUpper and lower conveyor belts of the main laminating unit are equipped with \u003cstrong\u003eroller brush cleaners\u003c\/strong\u003e to remove EVA\/film residue from the high-temperature cloth.\u003c\/li\u003e\n\u003cli\u003eThe heating plate is equipped with a \u003cstrong\u003especial blowing device\u003c\/strong\u003e (on 2658\/2666 models) to prevent the high-temperature cloth from sticking to the plate surface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e5.3 Unloading \/ Discharge Section\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDischarge conveyed by \u003cstrong\u003estainless steel rollers\u003c\/strong\u003e driven by frequency conversion system, speed adjustable to match feed and host machine speed.\u003c\/li\u003e\n\u003cli\u003eOptional: \u003cstrong\u003ebuffer-type stainless steel roller unloading\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003ePhotoelectric sensors at front and rear ends monitor discharge in real-time to prevent modules from falling.\u003c\/li\u003e\n\u003cli\u003eThe discharge section includes a \u003cstrong\u003efan cooling function\u003c\/strong\u003e — fans activate automatically when modules are discharged to accelerate cooling.\u003c\/li\u003e\n\u003cli\u003eDouble-layer models (BT2787, 2787DD) use \u003cstrong\u003estacked multi-roller conveyors\u003c\/strong\u003e with integrated air coolers for accelerated module cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e5.4 Transmission System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain machine transmission: \u003cstrong\u003eGear motor + frequency control speed + encoder control\u003c\/strong\u003e, driving high-temperature cloth via chain. Repeat positioning accuracy: ±10 mm.\u003c\/li\u003e\n\u003cli\u003eFeeding and discharging stages: Gear motor + frequency control speed to match main engine speed.\u003c\/li\u003e\n\u003cli\u003eHigh-temperature cloth is arranged in a \u003cstrong\u003elarge-cycle circular motion\u003c\/strong\u003e — multiple cloths connected in series, continuously circulating without disconnection during the entire transmission process. The connection\/join points of upper and lower cloths do NOT contact the module surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynchronous gear design\u003c\/strong\u003e ensures upper and lower high-temperature cloth systems always move in synchrony.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChain tensioning design + anti-jumping gear device\u003c\/strong\u003e reduces chain looseness from wear, ensuring smooth, continuous transmission without chain breakage or jumping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e5.5 Lifting System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBoth laminating and curing stages use \u003cstrong\u003epneumatic lifting\u003c\/strong\u003e, controlled by three-position five-way solenoid valves.\u003c\/li\u003e\n\u003cli\u003eKey pneumatic components (cylinders, lifting solenoid valves, pneumatic solenoid valves) use \u003cstrong\u003eJapanese SMC\u003c\/strong\u003e (or equivalent reputable) brand components.\u003c\/li\u003e\n\u003cli\u003eEach cylinder's inlet and outlet are equipped with \u003cstrong\u003eexhaust throttle valves\u003c\/strong\u003e to adjust lifting speed, ensuring stable and synchronous cylinder movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent air control safety system:\u003c\/strong\u003e A dedicated air safety circuit — separate from the main hoisting mechanism — provides a holding signal for each cylinder. This prevents the upper chamber from falling due to power outages, pipe bursts, or other abnormal causes.\u003c\/li\u003e\n\u003cli\u003eDouble-layer 2787DD model: Uses \u003cstrong\u003e8-column pneumatic lifting\u003c\/strong\u003e arrangement per chamber for stability on the large-format platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e5.6 Heating System (Oil Heating Models)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe heating plate is heated by \u003cstrong\u003eheat-conducting oil\u003c\/strong\u003e circulating through a perforated\/drilled plate. \u003cstrong\u003eDouble-inlet and double-outlet\u003c\/strong\u003e pipeline design for uniform temperature distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating rate:\u003c\/strong\u003e ≥1.5°C\/min.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature deviation:\u003c\/strong\u003e ≤±2°C (standard); ≤±1.5°C (BT2787, 2658 single-chamber).\u003c\/li\u003e\n\u003cli\u003eMulti-point temperature control with \u003cstrong\u003ePID self-tuning technology\u003c\/strong\u003e (standard temperature module). Achieves excellent temperature uniformity.\u003c\/li\u003e\n\u003cli\u003eHeating station from qualified manufacturers: provides \u003cstrong\u003ereal-time monitoring of temperature and pressure\u003c\/strong\u003e, with automatic alarm and shutdown on over-temperature or over-pressure conditions.\u003c\/li\u003e\n\u003cli\u003eBT2787 uses \u003cstrong\u003eSD320 thermal oil\u003c\/strong\u003e with four sets of 72 kW heating stations.\u003c\/li\u003e\n\u003cli\u003eOil tank over-temperature alarm: engine stops and alarms if oil temperature exceeds 180°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating procedure:\u003c\/strong\u003e Allow oil pump to run in normal circulation for at least 3 minutes before turning on heating. When shutting down: stop heating first, then turn off the oil pump. Do NOT turn off the hot oil pump when temperature is above 100°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e5.7 Vacuum System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLamination chamber vacuum controlled by a \u003cstrong\u003ehigh-vacuum butterfly valve\u003c\/strong\u003e (Roots pump set).\u003c\/li\u003e\n\u003cli\u003eUnder working temperature conditions, the ultimate vacuum of the lamination chamber can reach \u003cstrong\u003ebelow 40 Pa\u003c\/strong\u003e. In automatic operation mode, lamination chamber vacuum ≤100 Pa.\u003c\/li\u003e\n\u003cli\u003eEach chamber is equipped with a \u003cstrong\u003eJapanese SMC zero differential pressure pneumatic membrane two-way solenoid valve (VXZ260KG)\u003c\/strong\u003e for vacuum chamber inflation. Inflation rate freely adjustable from 0–50 L\/s (or 0–70 L\/s on OTCY-2787D).\u003c\/li\u003e\n\u003cli\u003eEach chamber has an \u003cstrong\u003eSMC pressure sensor\u003c\/strong\u003e for real-time chamber pressure monitoring. Touch screen displays live pressure. Lower chamber additionally equipped with a Pa-class vacuum gauge.\u003c\/li\u003e\n\u003cli\u003eThe entire vacuum\/pneumatic system is equipped with a \u003cstrong\u003emanual backup operating system\u003c\/strong\u003e for manual inflation and venting during unexpected power failure, minimizing losses from fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e5.8 Control System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhole equipment controlled by \u003cstrong\u003ePLC (Siemens) + Touch Screen (Kunlun Tongtai)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-recipe storage:\u003c\/strong\u003e Various process recipes (formulas) can be saved and recalled at any time, accommodating different manufacturers and material batches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData persistence:\u003c\/strong\u003e Process parameters and setting data are automatically memorized and stored on every power cycle — no loss of settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamination count statistics:\u003c\/strong\u003e Records production count per shift for scheduling, maintenance planning, and consumable replacement tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMES integration:\u003c\/strong\u003e Optional production process management system (MES) available upon user request.\u003c\/li\u003e\n\u003cli\u003eThree production modes selectable by operator: \u003cstrong\u003eManual, Semi-automatic, and Automatic\u003c\/strong\u003e. If an abnormality occurs during automatic operation, the machine can switch to manual mode to reduce losses.\u003c\/li\u003e\n\u003cli\u003eThree-stage lamination supported; vacuum and pressure values are independently set and controlled for each stage.\u003c\/li\u003e\n\u003cli\u003eHigh-end brand electrical components: superior performance, reliable quality, low replacement rate.\u003c\/li\u003e\n\u003cli\u003eEquipment cabling, piping, and installation accessories comply with \u003cstrong\u003enational standards and relevant regulations\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eBT2787 features \u003cstrong\u003eindependent double touch screens\u003c\/strong\u003e (one per layer) for simultaneous independent control of each production layer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e6. Safety Control\u003c\/h2\u003e\n\u003ch3\u003e6.1 Alarm \u0026amp; Protection Functions (Oil Heating Models)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eAlarm \/ Control Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaminate Module Positioning\u003c\/td\u003e\n\u003ctd\u003eIf modules are outside the orientation range, lamination is inhibited and an alarm is triggered.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Station High\/Low Level\u003c\/td\u003e\n\u003ctd\u003eIndependent liquid level detection device monitors oil level continuously. Alarm is triggered if level goes out of range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Tank Over-Temperature\u003c\/td\u003e\n\u003ctd\u003eIf heated oil temperature exceeds 180°C, the engine stops and alarm is triggered.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Plate Over-Temperature\u003c\/td\u003e\n\u003ctd\u003eMax and min temperature limits are set for the heating plate. Alarm is triggered if temperature goes beyond the set range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Pressure Detection\u003c\/td\u003e\n\u003ctd\u003eAlarm is triggered if oil pressure exceeds the set value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Source Pressure Detection\u003c\/td\u003e\n\u003ctd\u003eAlarm is triggered if compressed air pressure goes beyond the set range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Alarm\u003c\/td\u003e\n\u003ctd\u003eAlarm triggered if the vacuum level fails to reach the set value within the stipulated time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Pump Overload Protection\u003c\/td\u003e\n\u003ctd\u003eEngine alarms if oil pump is overloaded.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump Protection\u003c\/td\u003e\n\u003ctd\u003eMonitors vacuum pump working state and triggers alarm on failure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e6.2 Alarm \u0026amp; Protection Functions (Electric Heating \/ Semi-Auto Models)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eAlarm \/ Control Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Plate Over-Temperature\u003c\/td\u003e\n\u003ctd\u003eMax and min temperature limits set. Alarm if temperature exceeds set value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Source Pressure Detection\u003c\/td\u003e\n\u003ctd\u003eAlarm if air pressure exceeds set value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Alarm\u003c\/td\u003e\n\u003ctd\u003eAlarm if vacuum pressure fails to reach set value within stipulated time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump Protection\u003c\/td\u003e\n\u003ctd\u003eMonitors vacuum pump working state; alarms on breakdown.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Current Protection\u003c\/td\u003e\n\u003ctd\u003eMonitors and protects heating current; alarms on over-current or overload.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen\/Close Cover System\u003c\/td\u003e\n\u003ctd\u003eIn automatic mode, if the specified cover command is not met within the set time, system alarms.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Recording Function\u003c\/td\u003e\n\u003ctd\u003eRecords alarm time and cancellation time accurately. Up to 100 operating parameter records with export\/storage capability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e6.3 Anti-Drop Safety (All Models)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual safety measures: \u003cstrong\u003epilot-operated air control valve + mechanical lock\u003c\/strong\u003e. The upper cover will not fall when the equipment is suddenly powered off or the pipeline is faulty, preventing lamination failure and personnel injury.\u003c\/li\u003e\n\u003cli\u003eAn \u003cstrong\u003eindependent air control safety system\u003c\/strong\u003e prevents the upper chamber from falling due to power failures or burst pipes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e6.4 Other Safety Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety warning signs on all relevant parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-color lights and alarm system\u003c\/strong\u003e for real-time equipment operation status monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess password protection:\u003c\/strong\u003e Modification of process parameters requires authorized password entry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum indicator:\u003c\/strong\u003e In case of sudden power failure, lamination status can be assessed and appropriate action taken.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation measures:\u003c\/strong\u003e All pipelines and heating parts are thermally insulated to reduce energy consumption and temperature loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency stop button:\u003c\/strong\u003e Powers off the whole machine when pressed. Reset by rotating in the arrow direction on the button.\u003c\/li\u003e\n\u003cli\u003eVacuum pipe between vacuum pump and laminator should not exceed 12 meters to maintain vacuum performance.\u003c\/li\u003e\n\u003cli\u003eBefore opening the cover, confirm that the lower chamber has been inflated to atmosphere. Opening the cover under negative pressure is strictly prohibited.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e7. Key Components \u0026amp; Brands\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eBrand (Full-Auto Oil Models)\u003c\/th\u003e\n\u003cth\u003eBrand (Semi-Auto Electric Models)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Screen\u003c\/td\u003e\n\u003ctd\u003eKunlun Tongtai\u003c\/td\u003e\n\u003ctd\u003eKunlun Tongtai\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003ctd\u003eSchneider\u003c\/td\u003e\n\u003ctd\u003eSchneider\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Contactor\u003c\/td\u003e\n\u003ctd\u003eSchneider\u003c\/td\u003e\n\u003ctd\u003eSchneider\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolid State Relay\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Cylinder\u003c\/td\u003e\n\u003ctd\u003eJapanese SMC\u003c\/td\u003e\n\u003ctd\u003eAirTAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Regulator\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eAirTAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Sensor\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInflation Valve (Solenoid)\u003c\/td\u003e\n\u003ctd\u003eSMC VXZ260KG\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Butterfly Valve\u003c\/td\u003e\n\u003ctd\u003eShanhai Biaorui (high-vacuum)\u003c\/td\u003e\n\u003ctd\u003eShanhai Biaorui \/ China Shanhai\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eButterfly Valve (small models)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eFLOWX (OCY-H600D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump\u003c\/td\u003e\n\u003ctd\u003eSichuang Nanguang (2X-70)\u003c\/td\u003e\n\u003ctd\u003eSichuang Nanguang \/ Feiyue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Temperature Cloth\u003c\/td\u003e\n\u003ctd\u003eJiangsu\u003c\/td\u003e\n\u003ctd\u003eJiangsu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicone Membrane Sheet\u003c\/td\u003e\n\u003ctd\u003eShandong \/ Jiangsu\u003c\/td\u003e\n\u003ctd\u003eShandong \/ Jiangsu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e8. Factory \/ Installation Requirements (General)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C – 45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Line\u003c\/td\u003e\n\u003ctd\u003eAC380V ±5%, 3-phase 5-wire. For distance\u0026lt;50 m with good heat dissipation, a single 50 mm² (3+2) GB copper cable per supply is acceptable. Increase wire diameter as appropriate for longer runs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Source Connector\u003c\/td\u003e\n\u003ctd\u003e12 mm PU tube. Air pressure: 0.6–0.8 MPa (min 0.6 MPa per DIN ISO 8573-1). Flow: per model specification (see comparison table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Water (vacuum pump)\u003c\/td\u003e\n\u003ctd\u003eIndustrial circulating cooling water per GB50050-2007. Flow: 600 L\/h (2X-70 pump) + 960 L\/h (Roots pump). Interface: 1\/2″ (2X-70 pump). Customer to provide self-priming pump if needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClean Room Level\u003c\/td\u003e\n\u003ctd\u003eISO Class 5 (for large-format automatic models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor Flatness\u003c\/td\u003e\n\u003ctd\u003e±10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Conditioning\u003c\/td\u003e\n\u003ctd\u003e25 ± 5°C (temperature-controlled workshop recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Bearing\u003c\/td\u003e\n\u003ctd\u003ePer model weight (see individual specs). OTCY-2787DD: 3.0 T\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e9. Warranty \u0026amp; After-Sales Service\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Period:\u003c\/strong\u003e One year after successful installation, or 16 months from bill of lading date — whichever is earlier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e During the warranty period, the seller provides timely maintenance services and necessary spare parts free of charge (excluding consumables). Courier costs for spare parts are the buyer's responsibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-site Support:\u003c\/strong\u003e If buyer's engineers cannot resolve an issue during the warranty period, the seller will dispatch engineers to the buyer's plant. Round-trip airfare, local transport, accommodation, and meals in the buyer's city are at the buyer's expense.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Exclusions:\u003c\/strong\u003e Damage or malfunctions arising from misuse, abuse, self-demolition or modification by any party other than the seller's authorized technicians, or use inconsistent with the operation manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost-Warranty Support:\u003c\/strong\u003e The seller continues to provide free online service and technical guidance indefinitely after the warranty period. Spare parts are supplied to the buyer at favorable prices. On-site engineer visits after warranty: buyer covers airfare, visa, accommodation, travel expenses, and labor costs per the seller's standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsumables:\u003c\/strong\u003e Provided upon payment at all times (not covered under warranty).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperator Training:\u003c\/strong\u003e After installation and commissioning, machines must be operated only by trained personnel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e10. Operating \u0026amp; Safety Notes (User Manual Extract)\u003c\/h2\u003e\n\u003cp\u003eExtracted from the Ooitech Laminator Operating Instruction manual (Model A2236 and applicable to all full-auto models).\u003c\/p\u003e\n\u003ch3\u003e10.1 Symbol Guide\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003cth\u003eMeaning \/ Warning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e⚠ Be Careful\u003c\/td\u003e\n\u003ctd\u003eRisk of bump or tripping in this area. Pay attention to limb and body safety.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e???? High Temperature\u003c\/td\u003e\n\u003ctd\u003eWorkbench temperature can reach up to 180°C during and after operation. Confirm temperature is in safe range before touching. Do NOT loosen oil pipeline joints or flanges during or after operation while oil is still hot. Do NOT remove heating box protective panels arbitrarily.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e✋ Watch Your Hands\u003c\/td\u003e\n\u003ctd\u003eUpper box cover falling hazard. Ensure no personnel are in the working area when the machine is operating or being serviced.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e⚙ Mechanical Wounding\u003c\/td\u003e\n\u003ctd\u003eConveyor chains and belts can cause entanglement. All personnel in the production area must wear work clothes and work caps. Long hair must be fully tucked into the cap.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e⚡ Electric Shock\u003c\/td\u003e\n\u003ctd\u003ePower distribution cabinet installed in equipment area. Contact maintenance electrician for any electrical operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e10.2 Key Operating Precautions\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDo not use this product in corrosive gas, moisture, flammable, or explosive environments.\u003c\/li\u003e\n\u003cli\u003eEnsure the machine is properly grounded before operation.\u003c\/li\u003e\n\u003cli\u003eDo not open the terminal protective cover when the device is powered or running.\u003c\/li\u003e\n\u003cli\u003eDo not touch the circuit board with bare hands — risk of electric shock and ESD damage.\u003c\/li\u003e\n\u003cli\u003eOperators must wear insulated gloves when manually placing or removing laminated modules.\u003c\/li\u003e\n\u003cli\u003eMaintenance personnel must power off the machine before maintenance. Verify no danger exists before wiring, checking, or moving the machine.\u003c\/li\u003e\n\u003cli\u003eWhen starting or closing the machine, keep hands away from the main unit. In emergency, press the emergency stop button immediately.\u003c\/li\u003e\n\u003cli\u003eDuring belt\/chain transmission movement, non-operators must leave the area. Operators must not place hands or body parts near or into the conveyor belt.\u003c\/li\u003e\n\u003cli\u003eWhen machine is in working condition, all non-operators must stand at least 1 meter from the machine.\u003c\/li\u003e\n\u003cli\u003eVisitors and non-professionals are not allowed to operate this machine.\u003c\/li\u003e\n\u003cli\u003eThe vacuum pipe between vacuum pump and laminator must not exceed 12 meters — longer distances degrade vacuum performance.\u003c\/li\u003e\n\u003cli\u003eWhen shutting down the vacuum pump, first inflate both chambers to atmospheric pressure. The cover must NEVER be opened while the lower chamber is under negative pressure.\u003c\/li\u003e\n\u003cli\u003eAllow the oil pump to run in normal circulation for at least 3 minutes before turning on heating. When shutting down: stop heating first, then turn off the oil pump. Never turn off the hot oil pump when temperature is above 100°C.\u003c\/li\u003e\n\u003cli\u003eWhen the machine is not actively working, open the cover to allow heat dissipation after stopping heating.\u003c\/li\u003e\n\u003cli\u003eTurn off the main power supply after laminator operation is complete, to avoid interference with associated equipment.\u003c\/li\u003e\n\u003cli\u003eDo not slide or place sharp objects (e.g. blades) on the conveyor belt surface — this will shorten belt service life.\u003c\/li\u003e\n\u003cli\u003eThe automatic laminator has high precision electrical components. Do not arbitrarily reposition or redirect any electrical component — this may cause malfunction.\u003c\/li\u003e\n\u003cli\u003eDo not place any foreign objects on the heating platform surface — the cover exerts significant pressure during operation.\u003c\/li\u003e\n\u003cli\u003eBefore opening the cover, always verify the lower chamber has been inflated to atmosphere.\u003c\/li\u003e\n\u003cli\u003eThe emergency stop button powers off the entire machine. Reset by rotating the button in the direction indicated by the arrow after troubleshooting.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e10.3 Model Code Interpretation (from User Manual)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eSemi-automatic\u003c\/td\u003e\n\u003ctd\u003eOCY-H600D → Semi-auto, 600 mm, Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eSingle chamber\u003c\/td\u003e\n\u003ctd\u003eOTCY-A2658 → Single chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003eDouble chamber\u003c\/td\u003e\n\u003ctd\u003eOTCY-S2658 → Double chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eTriple chamber\u003c\/td\u003e\n\u003ctd\u003eOTCY-T2787 → Triple chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eDouble layer\u003c\/td\u003e\n\u003ctd\u003eOTCY-BT2787 → Double layer, Triple chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD (suffix)\u003c\/td\u003e\n\u003ctd\u003eElectric heating\u003c\/td\u003e\n\u003ctd\u003eOCY-H600D → Electric; 2787DD → Double Layer Double Chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumeric part\u003c\/td\u003e\n\u003ctd\u003eEffective laminating area (abbreviated dimensions)\u003c\/td\u003e\n\u003ctd\u003e2787 → ~2700×8700 mm area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Ooitech","offers":[{"title":"Default Title","offer_id":67691750916195,"sku":null,"price":347000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0560\/1427\/4659\/files\/w800_h600_fitblur_v2_1774438298752758.webp?v=1791858173","url":"https:\/\/ooitechchina.myshopify.com\/en-global\/products\/ooitech-solar-panel-laminator-complete-product-catalogue","provider":"Solar Panel Making Machine","version":"1.0","type":"link"}