{"product_id":"solar-panel-testing-equipment-for-iec-certification","title":"Solar Panel Testing Equipment for IEC Certification","description":"\u003cblockquote\u003e\n\u003cp\u003eOoitech offers a complete range of solar panel testing equipment for IEC61215 and IEC61730 certification, including visual inspection stations, wet leakage testers, steady state simulators, UV aging chambers, damp heat test chambers, mechanical load teste\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cimg alt=\"Solar Panel Testing Equipment for IEC Certification | Complete PV Module Test Solutions by Ooitech\" src=\"https:\/\/cdn.ooitech.com\/runtime\/image\/w800_h600_fitblur_v2_2026032716200590.webp\"\u003e\u003c\/p\u003e\n\u003ch4\u003eSolar Panel Testing Equipment for IEC Certification | Complete PV Module Test Solutions by Ooitech\u003c\/h4\u003e\n\u003cp\u003eOoitech offers a complete range of solar panel testing equipment for IEC61215 and IEC61730 certification, including visual inspection stations, wet leakage testers, steady state simulators, UV aging chambers, damp heat test chambers, mechanical load teste\u003c\/p\u003e\n\u003chr\u003e\n\u003chr\u003e\n\u003ch2\u003eVisual Inspection\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61215-2MQT01    IEC61730-2MST01\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Detect and record any appearance defects and changes in PV modules.\u003c\/p\u003e\n\u003ch3\u003eMain Technical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum test sample size\u003c\/th\u003e\n\u003cth\u003e2600mm × 1400mm (customizable)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport material\u003c\/td\u003e\n\u003ctd\u003eEuropean standard aluminum profile frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest platform\u003c\/td\u003e\n\u003ctd\u003e5mm all steel wood + blue insulating pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIllumination of test platform\u003c\/td\u003e\n\u003ctd\u003e≥ 1000 lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther accessories\u003c\/td\u003e\n\u003ctd\u003eDrawer, illuminometer, magnifying glass with scale, steel ruler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional accessories\u003c\/td\u003e\n\u003ctd\u003eCamera\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWet Leakage Test System\u003c\/h2\u003e\n\u003cp\u003eMeeting standard: IEC61215-2MQT15    IEC61730 MST17\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e To evaluate the insulation performance of the module under wet working conditions, and verify that the moisture of rain, fog, dew or snow cannot enter the working part of the internal circuit of the module. If the moisture enters, it may cause corrosion, electric leakage or safety accidents.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe liquid temperature can be automatically controlled; the temperature control system adopts a constant temperature all-in-one machine to accurately control the water temperature.\u003c\/li\u003e\n\u003cli\u003eIt can monitor the conductivity and temperature of liquid.\u003c\/li\u003e\n\u003cli\u003eEquipped with insulation tester, which can test the insulation and leakage of components.\u003c\/li\u003e\n\u003cli\u003eWith overload, overcurrent and overvoltage alarm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTemperature Control Tank\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe insulation tank is made of PPR material, which has good visibility and can observe the condition in the test process.\u003c\/li\u003e\n\u003cli\u003eAluminum alloy profile support, universal brake casters installed at the bottom, drain valve for easy cleaning.\u003c\/li\u003e\n\u003cli\u003ePID automatic temperature control adjustment to meet the standard requirements of 22±2℃ (the equipment has heating and cooling functions).\u003c\/li\u003e\n\u003cli\u003eConductivity range: 1.0~2000 μS\/cm (equivalent to 500Ω·cm ~ 1,000,000Ω·cm).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInsulation Test System\u003c\/h3\u003e\n\u003cp\u003eMeet: IEC61215-2MQT03    IEC61730-2MST16    IEC61730-2MST17\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Determine whether the insulation between live parts and accessible parts in the assembly is good.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWithstand voltage output\u003c\/th\u003e\n\u003cth\u003e0.1–10KV (Up to 15kV)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% of setting + 5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation voltage output\u003c\/td\u003e\n\u003ctd\u003e500–2000V (Upgradeable to 2500V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage accuracy (insulation)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% of setting + 10V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance range\u003c\/td\u003e\n\u003ctd\u003e100KΩ – 99GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance accuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% of setting + 10 counts) at \u0026gt;500±(7% of setting + 10 counts) at\u0026lt;500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSteady State Simulator\u003c\/h2\u003e\n\u003cp\u003eMeeting standard: IEC61215-2MQT09    IEC61730-2MST21    IEC61730-2MST22\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e To determine the ability of components to withstand the heating effect of hot spots, such as this effect may lead to welding melting or package degradation. Defective, mismatched, partially shaded or soiled batteries can cause this defect.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic load calculation, reasonable adjustment of system output and automatic compensation of light intensity.\u003c\/li\u003e\n\u003cli\u003eThe number of light sources is small and the light is powerful. Each lamp is equipped with independent EPS to realize 50%–100% adjustable light intensity.\u003c\/li\u003e\n\u003cli\u003eUnique reflector technology and computer simulation array arrangement ensure good irradiation uniformity.\u003c\/li\u003e\n\u003cli\u003eThe unique air duct design and efficient refrigeration unit can accurately control the temperature and wind speed, and the temperature control elements can be freely selected by program. The sample surface temperature control option ensures the test requirements of the sample temperature arrival time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMain Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLight source type\u003c\/th\u003e\n\u003cth\u003eMetal halogen lamp\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral distribution\u003c\/td\u003e\n\u003ctd\u003e280nm to 3000nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrradiation intensity\u003c\/td\u003e\n\u003ctd\u003e1000W\/㎡ to 1300W\/㎡\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrradiation intensity adjustment range\u003c\/td\u003e\n\u003ctd\u003e50% to 100% linear adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStudio size\u003c\/td\u003e\n\u003ctd\u003eCustomizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnevenness\u003c\/td\u003e\n\u003ctd\u003eClass B (≤5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral grade\u003c\/td\u003e\n\u003ctd\u003eClass B (300nm to 1200nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstability\u003c\/td\u003e\n\u003ctd\u003eClass A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e50℃±10℃ (expandable: -45℃ to 150℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity range\u003c\/td\u003e\n\u003ctd\u003e20% to 95% (humidity control can be added for high-temp\/high-humidity or damp-heat simulation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature deviation\u003c\/td\u003e\n\u003ctd\u003e≤2℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp source power\u003c\/td\u003e\n\u003ctd\u003e2KW \/ 4KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigeration system\u003c\/td\u003e\n\u003ctd\u003eSingle stage refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor brand\u003c\/td\u003e\n\u003ctd\u003eBizel, Germany \/ Taikang, France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling method\u003c\/td\u003e\n\u003ctd\u003eAir \/ water cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeet the standard\u003c\/td\u003e\n\u003ctd\u003eIEC + UL — Accept non-standard customization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eUltraviolet Aging Test Chamber (UV)\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61215-2MQT10    IEC61730-2MST54\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Conduct UV irradiation pretreatment before thermal cycling \/ wet freezing test of components to determine the UV attenuation of relevant materials and adhesive connections.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnique reflector technology and computer simulation array arrangement ensure good irradiation uniformity.\u003c\/li\u003e\n\u003cli\u003eThe unique air duct design and efficient refrigeration unit can accurately control the temperature and wind speed, and temperature control elements can be freely selected by program. The sample surface temperature control option ensures the test requirements of the sample temperature arrival time.\u003c\/li\u003e\n\u003cli\u003eThe number of light sources is small and the light is powerful. Each lamp is equipped with independent EPS and can be controlled independently.\u003c\/li\u003e\n\u003cli\u003eAutomatic load calculation, reasonable adjustment of system output and automatic compensation of light intensity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMain Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLight source type\u003c\/th\u003e\n\u003cth\u003eMetal halogen lamp\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral distribution\u003c\/td\u003e\n\u003ctd\u003e280nm to 400nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrradiation intensity\u003c\/td\u003e\n\u003ctd\u003e≥200W\/㎡\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrradiation intensity adjustment range\u003c\/td\u003e\n\u003ctd\u003e50% to 100% linear adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStudio size\u003c\/td\u003e\n\u003ctd\u003eCustomizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnevenness\u003c\/td\u003e\n\u003ctd\u003e≤15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral scale\u003c\/td\u003e\n\u003ctd\u003eUVB accounts for 3%–10% of the total UVA + UVB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e60℃±5℃ (expandable: -45℃ to 150℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity range\u003c\/td\u003e\n\u003ctd\u003e20% to 95% (humidity control can be added for high-temp\/high-humidity or damp-heat UV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature deviation\u003c\/td\u003e\n\u003ctd\u003e≤2℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp source power\u003c\/td\u003e\n\u003ctd\u003e2KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigeration system\u003c\/td\u003e\n\u003ctd\u003eSingle stage refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor brand\u003c\/td\u003e\n\u003ctd\u003eBizel, Germany \/ Taikang, France\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling method\u003c\/td\u003e\n\u003ctd\u003eAir \/ water cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeet the standard\u003c\/td\u003e\n\u003ctd\u003eIEC + UL — Accept non-standard customization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHigh and Low Temperature Damp Heat Test Chamber\u003c\/h2\u003e\n\u003cp\u003eMeeting standard: IEC61215-2 MQT11   IEC61215-2 MQT21   IEC61730-2 MST52  IEC61215-2 MQT12   IEC61730-2 MST51   IEC61730-2 MST53  IEC61215-2 MQT13   IEC61730-2 MST55   IEC61730-2 MST56\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Determine the ability of components to withstand thermal mismatch, fatigue and other stresses caused by repeated temperature changes; determine the ability of the component to withstand the influence of high temperature, high humidity and subsequent sub-zero temperature; determine the ability of the component to withstand long-term moisture penetration.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExclusive patented layered blowing technology: short temperature rise\/fall time and better uniformity for tested samples.\u003c\/li\u003e\n\u003cli\u003eAutomatic load calculation, reasonable regulation of system output. The latest cooling capacity control technology (thermal expansion valve + capillary + cold output) changes the traditional heater-offset method of controlling box temperature, achieving 40% energy saving compared with the traditional way.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMain Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003cth\u003e-45℃ to 125℃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity range\u003c\/td\u003e\n\u003ctd\u003e20%–98% RH (between 20℃ and 90℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation layer thickness\u003c\/td\u003e\n\u003ctd\u003e≥150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking room size (D×W×H) mm\u003c\/td\u003e\n\u003ctd\u003eCustomizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature fluctuation\u003c\/td\u003e\n\u003ctd\u003e≤±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature uniformity\u003c\/td\u003e\n\u003ctd\u003e≤2℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature rise and fall rate\u003c\/td\u003e\n\u003ctd\u003eCustomizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity fluctuation\u003c\/td\u003e\n\u003ctd\u003e≤±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity uniformity\u003c\/td\u003e\n\u003ctd\u003e≤3%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigeration mode\u003c\/td\u003e\n\u003ctd\u003eCompressor refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigeration system\u003c\/td\u003e\n\u003ctd\u003eBinary superposition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor brand\u003c\/td\u003e\n\u003ctd\u003eBizel, Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling method\u003c\/td\u003e\n\u003ctd\u003eWater-cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeet the standard\u003c\/td\u003e\n\u003ctd\u003eIEC + UL — Accept non-standard customization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCurrent Continuity Monitoring System\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61215-2 MQT11   IEC61730-2 MST52   IEC61215-2 MQT12   IEC61730-2 MST51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Simulate the effect of long-term thermal expansion and cold contraction of photovoltaic modules on welding performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct features:\u003c\/strong\u003e Customer-defined relationship between current and temperature; built-in communication port with the environment chamber; temperature channels and current channels can be combined freely.\u003c\/p\u003e\n\u003ch3\u003eMain Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage\u003c\/th\u003e\n\u003cth\u003eThree-phase 380VAC ±15%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e47–63Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e0–100V (customizable), resolution: 0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current\u003c\/td\u003e\n\u003ctd\u003e0–30A (customizable), resolution: 0.001A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e3000W (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput efficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;90% (standard AC input, full load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHigh Temperature and Humidity Test Chamber (DH)\u003c\/h2\u003e\n\u003cp\u003eMeeting standard: IEC61215-2 MQT13   IEC61215-2 MQT21   IEC61730-2 MQT21   IEC62804\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e To determine the ability of the component to withstand long-term moisture penetration.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic load calculation, reasonable regulation of system output. The latest cooling capacity control technology (thermal expansion valve + capillary + cold output), achieving 40% energy saving compared with the traditional method.\u003c\/li\u003e\n\u003cli\u003eFull-welding cabin design to prevent moisture leakage, with higher load capacity.\u003c\/li\u003e\n\u003cli\u003eIntegrated sample fixture accommodates samples of different sizes, with full insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMain Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003cth\u003eRT–125℃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity range\u003c\/td\u003e\n\u003ctd\u003e20%–98% RH (between 20℃ and 90℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation layer thickness\u003c\/td\u003e\n\u003ctd\u003e≥150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking room size (D×W×H) mm\u003c\/td\u003e\n\u003ctd\u003eCustomizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature fluctuation\u003c\/td\u003e\n\u003ctd\u003e≤±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature uniformity\u003c\/td\u003e\n\u003ctd\u003e≤2℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature rise and fall rate\u003c\/td\u003e\n\u003ctd\u003eCustomizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity fluctuation\u003c\/td\u003e\n\u003ctd\u003e≤±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity uniformity\u003c\/td\u003e\n\u003ctd\u003e≤3%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling method\u003c\/td\u003e\n\u003ctd\u003eAir \/ water cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeet the standard\u003c\/td\u003e\n\u003ctd\u003eIEC + UL — Accept non-standard customization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePID Test System\u003c\/h2\u003e\n\u003cp\u003eMeeting standard: IEC61215-2 MQT21    IEC62804\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePID power supply has multi-channel output, which can provide multiple components for simultaneous testing; voltage is continuously adjustable and displayed in real time.\u003c\/li\u003e\n\u003cli\u003eThe power supplies are independent of each other and can output different polarity and different voltage values at the same time.\u003c\/li\u003e\n\u003cli\u003ePID monitors communication and outputs high voltage to test samples according to customer-defined time requirements. The system monitors internal temperature and humidity of the environmental test chamber in accordance with the latest standards (online communication with high-temperature and high-humidity equipment). When the environmental test chamber fails, the PID power supply automatically receives the fault information and forces output to \"0\", preventing damage to test samples and ensuring equipment safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMain Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage\u003c\/th\u003e\n\u003cth\u003eAC 220V ±10%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003eDC -2000V to +2000V (continuously adjustable); upgradeable to DC -2500V to +2500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd\u003eVoltage fluctuation within 500 hours of continuous output at 1000V \/ 1500V \/ 2000V: ≤0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum rated current\u003c\/td\u003e\n\u003ctd\u003e250 μA \/ passageway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent accuracy\u003c\/td\u003e\n\u003ctd\u003e1μA + 1% F·S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest channel\u003c\/td\u003e\n\u003ctd\u003eCustomer customization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eStatic Mechanical Load Test (Sand Pressure)\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61215-2MQT16    IEC61730-2 MST34\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Determine the ability of components to withstand static loads such as wind, snow or icing.\u003c\/p\u003e\n\u003ch3\u003eMain Equipment Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum size of test sample\u003c\/th\u003e\n\u003cth\u003e2600 × 1400mm (customizable)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum load of test equipment\u003c\/td\u003e\n\u003ctd\u003e≤12500 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure control accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% (self-prepared according to the number of sandbags)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit continuity system\u003c\/td\u003e\n\u003ctd\u003eDC power supply: 60V \/ 5A (customizable); real-time monitoring of internal continuity of components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSandbag specification\u003c\/td\u003e\n\u003ctd\u003e10.0 ± 0.25 kg\/bag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of shape variables\u003c\/td\u003e\n\u003ctd\u003e1–5 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape variable accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape variable range\u003c\/td\u003e\n\u003ctd\u003e±200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCustomized test platform fixture adjustable according to sample installation mode: long frame, short frame, and mounting hole installation modes are all supported.\u003c\/li\u003e\n\u003cli\u003eShape variable test system supports up to 5 monitoring points simultaneously; monitoring point positions are arbitrarily adjustable.\u003c\/li\u003e\n\u003cli\u003eVisual icon control and Excel output; current output control to meet diverse customer requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCyclic (Dynamic) Mechanical Load Testing (DML)\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61215-2MQT16   IEC61215-2MQT20   IEC61730-2 MST34   IEC TS62782:2016\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Determine the ability of components to withstand static and dynamic loads under conditions such as wind, snow or icing.\u003c\/p\u003e\n\u003ch3\u003eDesign Description\u003c\/h3\u003e\n\u003cp\u003eThe system simulates dynamic load using pneumatic cylinders with suction cups. Pressure mode: suction cup + pressure sensor + cylinder + proportional valve + PLC. Each cylinder drives one suction cup; a pull-pressure sensor is installed on each cylinder piston rod. Air pressure is calculated by PLC based on real-time feedback from the pressure sensors, and cylinder movement is controlled by adjusting the proportional valve opening to achieve precise force control. Each cylinder is an independent control module. Periodic load pressure tests are conducted on the installation plane of the component. The main frame is 8080 European standard aluminum profile, designed to accommodate conventional pressure block installation, screw hole installation, and double-glass component installation. The equipment also provides real-time monitoring of component shape variables, current continuity, and component temperature during testing.\u003c\/p\u003e\n\u003ch3\u003eMain Technical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePV module size\u003c\/th\u003e\n\u003cth\u003e≤2600 × 1400mm (customizable)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight range of PV module + mounting beam\u003c\/td\u003e\n\u003ctd\u003e50mm–350mm (compatible with sun-tracking installation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest capacity\u003c\/td\u003e\n\u003ctd\u003eOne module at a time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressurization mode\u003c\/td\u003e\n\u003ctd\u003eCylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cylinders\u003c\/td\u003e\n\u003ctd\u003e6×12 = 72 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of pressure sensors\u003c\/td\u003e\n\u003ctd\u003e6×12 = 72 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure sensor accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.02% F·S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure mode\u003c\/td\u003e\n\u003ctd\u003ePulling and pressing (two directions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBore stroke\u003c\/td\u003e\n\u003ctd\u003e300mm (-150mm ~ +150mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction cup center distance and edge distance\u003c\/td\u003e\n\u003ctd\u003e≤20cm (non-standard: separate specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder position (spacing movable)\u003c\/td\u003e\n\u003ctd\u003eCenter distance arbitrarily adjustable within 2600×1400mm range (150mm ~ 250mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest frequency\u003c\/td\u003e\n\u003ctd\u003e3~7 cycles\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDown pressure maximum pressure\u003c\/td\u003e\n\u003ctd\u003e12,000 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pull-up pressure\u003c\/td\u003e\n\u003ctd\u003e-7,200 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure control accuracy (static load)\u003c\/td\u003e\n\u003ctd\u003e1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction cup diameter\u003c\/td\u003e\n\u003ctd\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction cup variable angle\u003c\/td\u003e\n\u003ctd\u003e15°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic load non-uniformity (5 min)\u003c\/td\u003e\n\u003ctd\u003eTest pressure ≥2400 Pa: non-uniformity ≤3%Test pressure ≥3600 Pa: non-uniformity ≤2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic load non-uniformity (5 min)\u003c\/td\u003e\n\u003ctd\u003eTest pressure ≥1000 Pa: non-uniformity ≤5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape variable sensor\u003c\/td\u003e\n\u003ctd\u003e1~5 positions (movable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape variable sensor accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder brand\u003c\/td\u003e\n\u003ctd\u003eImported from Japan (original)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProportional valve brand\u003c\/td\u003e\n\u003ctd\u003eImported from Japan (original)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction cup brand\u003c\/td\u003e\n\u003ctd\u003eImported from Japan (original)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController brand\u003c\/td\u003e\n\u003ctd\u003eSiemens PLC (Germany)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl mode\u003c\/td\u003e\n\u003ctd\u003ePLC + HMI (Shanghai Houyao proprietary program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther\u003c\/td\u003e\n\u003ctd\u003eLow-temperature load option available: -40℃ (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower specification\u003c\/td\u003e\n\u003ctd\u003e60V 5A (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent installation method\u003c\/td\u003e\n\u003ctd\u003ePressure block installation, screw hole installation, sun-tracking bracket installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControl software synchronously collects pressure, component pressure, component temperature, continuity current, component voltage, and shape variable data for each cylinder.\u003c\/li\u003e\n\u003cli\u003eHumanized HMI graphics; arbitrary current setting to meet diverse customer needs.\u003c\/li\u003e\n\u003cli\u003eVisual icon display and Excel output format.\u003c\/li\u003e\n\u003cli\u003eOptional special load cell for periodic equipment verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHail Test\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61215-2MQT17\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Evaluate the ability of the component to withstand hail impact.\u003c\/p\u003e\n\u003ch3\u003eMain Technical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIce ball specifications\u003c\/th\u003e\n\u003cth\u003e25mm; 35mm; 45mm; 55mm; 65mm; 75mm (optional)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIce ball diameter accuracy\u003c\/td\u003e\n\u003ctd\u003e≤±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIce ball mass accuracy\u003c\/td\u003e\n\u003ctd\u003e≤±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIce ball generation speed control accuracy\u003c\/td\u003e\n\u003ctd\u003e≤±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed sensor accuracy\u003c\/td\u003e\n\u003ctd\u003e≤±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic balance\u003c\/td\u003e\n\u003ctd\u003e100g\/0.1mg; 250g\/0.1mg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerator\u003c\/td\u003e\n\u003ctd\u003e2 sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cp\u003eThe ice ball firing speed is measurable. The speed measuring unit uses two photoelectric sensors mounted in front of the transmitting tube, with a 10cm gap between them. Speed is calculated by V = S\/T and displayed in real time. The speed test device consists of three parts: detection sensor, high-speed response module, and software module. Photoelectric sensors and a programmable controller with stable performance are used for speed measurement.\u003c\/p\u003e\n\u003ch2\u003eBypass Diode Testing\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61215-2MQT18    IEC61730-2 MST25\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e To evaluate the thermal performance of bypass diodes and their long-term reliability against harmful effects such as hot spots.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe system automatically forms a fitting curve to judge test results.\u003c\/li\u003e\n\u003cli\u003eThe equipment is equipped with an oscilloscope to capture the pulse curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMain Equipment Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power supply — current\u003c\/th\u003e\n\u003cth\u003e30A (customizable), deviation ±2%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse power supply — pulse width\u003c\/td\u003e\n\u003ctd\u003e800 μs – 1100 μs adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForward constant current source — current\u003c\/td\u003e\n\u003ctd\u003e50A (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForward constant current source — accuracy\u003c\/td\u003e\n\u003ctd\u003e0.05% + 0.5% F·S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage acquisition channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature acquisition channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCut Susceptibility Test\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61730-2MQT12\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Determine whether polymer materials, as components of front and rear surfaces, can withstand routine operations during installation and maintenance without the risk of personal electric shock.\u003c\/p\u003e\n\u003ch3\u003eMain Technical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eA — Distance from rotating shaft to center point of bearing\u003c\/th\u003e\n\u003cth\u003e150mm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eB — Distance from rotating shaft to test point\u003c\/td\u003e\n\u003ctd\u003e170mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC — Carbon steel band thickness\u003c\/td\u003e\n\u003ctd\u003e0.64mm ± 0.05mm (saw blade recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD — Angle between carbon steel strip and horizontal plane\u003c\/td\u003e\n\u003ctd\u003e140°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQ — Force applied at point Q\u003c\/td\u003e\n\u003ctd\u003e8.9N ± 0.5N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR — Radius of arc at tip\u003c\/td\u003e\n\u003ctd\u003e0.115mm ± 0.025mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT — Angle of T\u003c\/td\u003e\n\u003ctd\u003e90° ± 2°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed requirement\u003c\/td\u003e\n\u003ctd\u003e150mm\/s ± 30mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eRobustness of Terminations\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61215-2MQT14    IEC61730-2 MST42\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e To determine whether the leading-out end and its attachment to the component can withstand the force during normal installation and operation.\u003c\/p\u003e\n\u003ch3\u003eMain Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTorsion test — test duration\u003c\/th\u003e\n\u003cth\u003e1 min (settable)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorsion test — deflection angle\u003c\/td\u003e\n\u003ctd\u003eDisplay \/ physical display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive force test — load\u003c\/td\u003e\n\u003ctd\u003e40N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive force test — test time\u003c\/td\u003e\n\u003ctd\u003e10 ± 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive force test — control mode\u003c\/td\u003e\n\u003ctd\u003ePLC control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive force test — fixture\u003c\/td\u003e\n\u003ctd\u003eJunction box custom fixture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile test — weight configuration\u003c\/td\u003e\n\u003ctd\u003e4N, 30N, 40N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile test — test frequency\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eContinuity Test of Equipotential Bonding\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61730-2MQT13\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Prove that all exposed conductor surfaces of the assembly are connected and grounded to each other.\u003c\/p\u003e\n\u003cp\u003eThe BSQ9930A photovoltaic grounding resistance tester is specially designed for the grounding resistance characteristics of photovoltaic modules (also known as grounding continuity tester). Programmable output test current DC 10~100A, test range up to 0.01μΩ~600mΩ, stable test and high precision. It has test line conductivity detection function, three groups of test modes, and can realize programmable test and sorting. RS485 interface is optional; instrument networking can be easily realized through Modbus communication protocol. Complies with photovoltaic standard IEC61730.\u003c\/p\u003e\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDC output 10A–100A, capable of meeting three times the maximum current of a photovoltaic panel.\u003c\/li\u003e\n\u003cli\u003eResistance test range: 0.01μΩ ~ 600mΩ, stable reading.\u003c\/li\u003e\n\u003cli\u003eTest line anomaly detection function to prevent test misjudgment.\u003c\/li\u003e\n\u003cli\u003eVarious interface configurations suitable for supporting automatic test systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMain Equipment Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTest parameter\u003c\/th\u003e\n\u003cth\u003eResistance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current and accuracy\u003c\/td\u003e\n\u003ctd\u003eProgram controlled DC 10A–100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest range\u003c\/td\u003e\n\u003ctd\u003e0.01μΩ – 600mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay accuracy\u003c\/td\u003e\n\u003ctd\u003e0.001A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum output power\u003c\/td\u003e\n\u003ctd\u003e600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest time\u003c\/td\u003e\n\u003ctd\u003e0.1S – 999.9S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComparator\u003c\/td\u003e\n\u003ctd\u003eThree groups of test conditions saved; audible and visual pass\/fail indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay results\u003c\/td\u003e\n\u003ctd\u003eCurrent, resistance, time, and sorting information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard interface\u003c\/td\u003e\n\u003ctd\u003eRS232C; RS485 (optional); PLC interface (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication protocol\u003c\/td\u003e\n\u003ctd\u003eModbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther\u003c\/td\u003e\n\u003ctd\u003eAbnormal alarm prompt for test line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower requirements\u003c\/td\u003e\n\u003ctd\u003eVoltage: 198VAC~240VAC; Frequency: 47Hz–63Hz; Power: 650VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize and weight\u003c\/td\u003e\n\u003ctd\u003e344(L) × 280(W) × 99(H) mm; Weight: 5.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eFour-terminal test clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eImpulse Voltage Test\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61730-2MST14\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e This test is used to verify the ability of solid insulating materials in components to withstand overvoltage caused by atmospheric environment. It also relates to the overvoltage state caused by the switching of low-voltage equipment.\u003c\/p\u003e\n\u003cp\u003eThe BSQ_PV30 is specially designed for testing the pulse voltage of solar cell modules (solar panels). The generator can generate surge voltage waveform 1.2\/50μs meeting IEC60060-1\/2 standard. The voltage can reach 30KV and meets the standard requirements of IEC61730-1\/2 and EN61730-1.\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse output voltage (adjustable ±3%)\u003c\/th\u003e\n\u003cth\u003e2.0~30KV\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd\u003e≤3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage resolution\u003c\/td\u003e\n\u003ctd\u003e10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise time\u003c\/td\u003e\n\u003ctd\u003e1.2 ± 30% μs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFalling time\u003c\/td\u003e\n\u003ctd\u003e50μs ± 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd\u003ePositive \/ Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum energy storage\u003c\/td\u003e\n\u003ctd\u003e100J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging time at maximum charging voltage\u003c\/td\u003e\n\u003ctd\u003eApproximately 10 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal load capacitance\u003c\/td\u003e\n\u003ctd\u003e4100pF ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSupporting Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope: 1 set\u003c\/li\u003e\n\u003cli\u003eAttenuation rod (attenuation multiple 1000:1): 1 set\u003c\/li\u003e\n\u003cli\u003eInsulation protection grade insulation pad: 2 pieces\u003c\/li\u003e\n\u003cli\u003eInsulating gloves: 1 pair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eReverse Current Overload Test\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61730-2MST26\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Evaluate the conductive material of the external insulation layer of the module. In case of reverse current fault and before the overcurrent protector disconnects the circuit, the battery and interconnection strip of the module will be forced to heat up to consume energy. This test is used to determine the resistance of components to ignition and fire under this state.\u003c\/p\u003e\n\u003ch3\u003eFunctional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 100A current can be supplied to components.\u003c\/li\u003e\n\u003cli\u003eThe reverse current can be set and monitored in real time (optional).\u003c\/li\u003e\n\u003cli\u003eHistorical data query function (optional).\u003c\/li\u003e\n\u003cli\u003eAll data exported in Excel format (optional).\u003c\/li\u003e\n\u003cli\u003eTemperature measurement range: -20℃ ~ 200℃, accuracy: 0.5℃ (optional).\u003c\/li\u003e\n\u003cli\u003ePine board can provide third-party thermal conductivity report.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Specification (BSQ6512D)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage\u003c\/th\u003e\n\u003cth\u003eThree-phase 380VAC ±15%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e47–63Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e0~100V (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current\u003c\/td\u003e\n\u003ctd\u003e0–100A (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e10kW (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent accuracy (constant current CC)\u003c\/td\u003e\n\u003ctd\u003e≤0.05% + 0.5% F·S (set value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage accuracy (constant voltage CV)\u003c\/td\u003e\n\u003ctd\u003e≤0.05% + 0.3% F·S (set value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e≥90% (standard AC input, full load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay mode\u003c\/td\u003e\n\u003ctd\u003eFour-digit LED nixie tube display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e4-bit display accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote analog monitoring\u003c\/td\u003e\n\u003ctd\u003eAnalog control, USB \/ LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote programming\/monitoring accuracy — voltage\u003c\/td\u003e\n\u003ctd\u003e2mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote programming\/monitoring accuracy — current\u003c\/td\u003e\n\u003ctd\u003e2mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eInput undervoltage, output overvoltage, overheating, short circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling mode\u003c\/td\u003e\n\u003ctd\u003eFan(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther accessories\u003c\/td\u003e\n\u003ctd\u003ePine board, rice paper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eModule Breakage Test\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC61730-2MST32\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e Determine the risk factor of scratch or stab after component rupture, and the toughening strength of toughened glass.\u003c\/p\u003e\n\u003ch3\u003eImpact Bag Specification\u003c\/h3\u003e\n\u003cp\u003eThe impact bag is a leather bag similar in shape and size to a hanging bag, filled with lead pellets (diameter 2.5~3.0mm, i.e. #7.5 shot) to the required weight. The outer surface of the bag is wrapped with tape; during testing, the impact bag is completely wrapped with 1.3cm-wide glass fiber-reinforced pressure-sensitive tape.\u003c\/p\u003e\n\u003ch2\u003eSalt Mist Test\u003c\/h2\u003e\n\u003cp\u003eMeet the standard: IEC60068-2-52    IEC61701-2011\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest purpose:\u003c\/strong\u003e To determine the corrosion resistance of components and their packaging materials.\u003c\/p\u003e\n\u003cp\u003eThe equipment uses saline solution or acidic saline solution and does not move the test sample in a test box to achieve four cycle (alternating) test effects: salt spray, drying, constant temperature and humidity at standard atmospheric pressure, and low-temperature storage. It accelerates corrosion of materials or products according to test requirements, and tests the damage degree within a certain time range.\u003c\/p\u003e\n\u003ch3\u003eMain Technical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature range\u003c\/th\u003e\n\u003cth\u003e10–100℃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature deviation\u003c\/td\u003e\n\u003ctd\u003e≤±1.0℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature repeatability\u003c\/td\u003e\n\u003ctd\u003e≤±0.5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature uniformity\u003c\/td\u003e\n\u003ctd\u003e≤2℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity range\u003c\/td\u003e\n\u003ctd\u003e25%–98% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity deviation\u003c\/td\u003e\n\u003ctd\u003e+2~-3% (\u0026gt;75%RH); ±5% (≤75%RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity fluctuation\u003c\/td\u003e\n\u003ctd\u003e≤1.5% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity uniformity\u003c\/td\u003e\n\u003ctd\u003e≤3% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt fog sedimentation\u003c\/td\u003e\n\u003ctd\u003eContinuously collect salt spray at any point in the exposed area for at least 8 hours using 80cm utensils; deposition rate: 1~2mL\/h (number of test utensils: 3×3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpray mode\u003c\/td\u003e\n\u003ctd\u003ePneumatic; continuous and intermittent spray freely adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir source pressure\u003c\/td\u003e\n\u003ctd\u003e0.17~0.4 mPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume of brine tank\u003c\/td\u003e\n\u003ctd\u003e≥500L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal bearing capacity\u003c\/td\u003e\n\u003ctd\u003e≥1000 kg\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest mode\u003c\/td\u003e\n\u003ctd\u003eConstant value and program test (salt spray and damp heat can be switched automatically)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample placement\u003c\/td\u003e\n\u003ctd\u003eBracket places component at 30° angle to the Y-axis direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt spray method\u003c\/td\u003e\n\u003ctd\u003eBaffle type — salt spray is not directly sprayed on the sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt fog indoor roof\u003c\/td\u003e\n\u003ctd\u003eTop included angle approximately 120° to prevent droplets from dripping directly on the sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor bin pressure\u003c\/td\u003e\n\u003ctd\u003eTwo 110×110mm automatic control balance windows installed at appropriate positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt spray test level\u003c\/td\u003e\n\u003ctd\u003eLevel 1–7 salt spray test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg alt=\"image.png\" src=\"https:\/\/cdn.ooitech.com\/static\/upload\/image\/20260327\/2026032720852804.webp\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"image.png\" src=\"https:\/\/cdn.ooitech.com\/static\/upload\/image\/20260327\/2026032793533202.webp\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"image.png\" src=\"https:\/\/cdn.ooitech.com\/static\/upload\/image\/20260327\/2026032720087500.webp\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"image.png\" src=\"https:\/\/cdn.ooitech.com\/static\/upload\/image\/20260327\/2026032788854903.webp\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"image.png\" src=\"https:\/\/cdn.ooitech.com\/static\/upload\/image\/20260327\/2026032720137794.webp\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"image.png\" src=\"https:\/\/cdn.ooitech.com\/static\/upload\/image\/20260327\/2026032719076667.webp\"\u003e\u003c\/p\u003e","brand":"Ooitech","offers":[{"title":"Default Title","offer_id":44198344392803,"sku":null,"price":99999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0560\/1427\/4659\/files\/w800_h600_fitblur_v2_2026032716200590.webp?v=1779418880","url":"https:\/\/ooitechchina.myshopify.com\/zh-global\/products\/solar-panel-testing-equipment-for-iec-certification","provider":"Solar Panel Making Machine","version":"1.0","type":"link"}